appliancetechhq Notes from the laundry and the kitchen

Home / Freezer repairs / Common problems and solutions / A freezer that is not freezing: temperature and airflow

Freezer

A freezer that is not freezing: temperature and airflow

Put a thermometer in the middle of the food, not in the door, and leave the door shut overnight. If the reading is nowhere near 0°F, move the control one step colder and wait another day. Moving it from warm to coldest in an hour tells you nothing.

While you wait, look at the load. Packages pressed over the rear vents stop the cold air. A freezer stuffed to the ceiling warms at the door even when the coil is fine. Pull the food back and retest before you order parts.

A cabinet that will not hold temperature with clear vents and a sane setting has left the "check the dial" stage. Heavy frost on the coil means defrost. A running compressor with no frost pattern at all, and clean condenser coils, leans toward the sealed system. The thermometer method itself is spelled out on the temperature settings page.