A single dead burner is usually local to that burner. The control and the supply are proven by the burners that still work.

Electric coil: pull the coil out of the receptacle. Look at the terminals for a burn mark, and look into the receptacle for the same. A receptacle that is brown and crisp has overheated and will kill a new coil. Replace the receptacle with the breaker off, then the coil. A coil that has a blister in the sheath is done even if the receptacle looks clean. Seat the coil fully. A half-seated coil arcs.

Gas: lift the cap and the burner head. Spillover plugs the ports. Clean them with a toothpick, dry the igniter, and set the cap flat. A burner that clicks and will not light, with clean ports and a good cap, often has a cracked igniter. The crack is a hairline in the white ceramic. That igniter is a part. If you smell gas and the burner does not light, shut the gas off at the range and ventilate. Do not keep the knob on while you adjust the cap.

A smooth-top radiant element is under the glass. Do not pry the glass up to look. If one zone stays cold and the others heat, the limiter or that element has opened, and the glass top comes off as a service procedure with the breaker off, not as a Saturday experiment.